Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 93
Filtrar
1.
Braz Dent J ; 22(5): 404-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22011897

RESUMO

The aim of this study was to evaluate the accuracy of linear measurements made on conventional and digitized periapical and panoramic radiographic images of dry human hemi-mandibles. Images from the posterior region of 22 dry human hemi-mandibles were obtained by conventional panoramic and periapical radiography technique. Using a digital caliper, 3 vertical measurements were marked directly on the dry hemi-mandibles (reference measurements) as well as on the tracing from the conventional radiographic images of the specimens made onto acetate paper sheet: Distance 1: between the upper limit of the alveolar ridge and the lower limit at the mandible base; Distance 2: between the upper limit of the alveolar ridge and the upper limit of the mandibular canal; Distance 3: between the lower limit of the mandibular canal and the lower limit of the mandible base. Next, the radiographs were digitized and the three measurements were made on the digital images using UTHSCSA Image Tool software. Data were analyzed statistically by one-way ANOVA (α=0.05). There was no statistically significant differences (p>0.05) between periapical and panoramic radiographs or between the measurements recorded using the digital caliper and UTHSCSA software compared with dry mandible specimens for Distances 1 (p=0.783), 2 (p=0.986) and 3 (p=0.129). In conclusion, the radiographic techniques evaluated in this study are reliable for vertical bone measurements on selected areas and the UTHSCA Image Tool software is an appropriate measurement method.


Assuntos
Cefalometria/normas , Mandíbula/diagnóstico por imagem , Radiografia Interproximal/normas , Radiografia Dentária Digital/normas , Radiografia Panorâmica/normas , Processo Alveolar/diagnóstico por imagem , Pontos de Referência Anatômicos/diagnóstico por imagem , Cefalometria/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/normas , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Radiografia Interproximal/estatística & dados numéricos , Radiografia Dentária Digital/estatística & dados numéricos , Radiografia Panorâmica/estatística & dados numéricos , Reprodutibilidade dos Testes , Software/normas , Software/estatística & dados numéricos
2.
Braz. dent. j ; 22(5): 404-409, 2011. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-601842

RESUMO

The aim of this study was to evaluate the accuracy of linear measurements made on conventional and digitized periapical and panoramic radiographic images of dry human hemi-mandibles. Images from the posterior region of 22 dry human hemi-mandibles were obtained by conventional panoramic and periapical radiography technique. Using a digital caliper, 3 vertical measurements were marked directly on the dry hemi-mandibles (reference measurements) as well as on the tracing from the conventional radiographic images of the specimens made onto acetate paper sheet: Distance 1: between the upper limit of the alveolar ridge and the lower limit at the mandible base; Distance 2: between the upper limit of the alveolar ridge and the upper limit of the mandibular canal; Distance 3: between the lower limit of the mandibular canal and the lower limit of the mandible base. Next, the radiographs were digitized and the three measurements were made on the digital images using UTHSCSA Image Tool software. Data were analyzed statistically by one-way ANOVA (α=0.05). There was no statistically significant differences (p>0.05) between periapical and panoramic radiographs or between the measurements recorded using the digital caliper and UTHSCSA software compared with dry mandible specimens for Distances 1 (p=0.783), 2 (p=0.986) and 3 (p=0.129). In conclusion, the radiographic techniques evaluated in this study are reliable for vertical bone measurements on selected areas and the UTHSCA Image Tool software is an appropriate measurement method.


O objetivo deste estudo foi avaliar a acurácia de medidas lineares realizadas em radiografias panorâmicas e periapicais convencionais e digitalizadas de hemimandíbulas humanas secas. Imagens da região posterior de 22 hemimandíbulas humanas secas foram obtidas pelas técnicas panorâmica e periapical convencionais. Com o paquímetro eletrônico digital, foram realizadas três medições verticais diretamente sobre as hemimandíbulas (medidas referenciais), bem como sobre o decalque das imagens convencionais, em papel de acetato: Distância 1: Distância entre o limite superior do rebordo alveolar e o limite inferior da base da mandíbula; Distância 2: Distância entre o limite superior do rebordo alveolar e o limite superior do canal mandibular e Distância 3: Distância entre o limite inferior do canal mandibular e o limite inferior da base da mandíbula. Posteriormente, as radiografias foram digitalizadas e as três medidas foram realizadas nas imagens digitais utilizando o programa UTHSCSA Image Tool. Os dados foram analisados estatisticamente pelo teste ANOVA a um critério (α=0,05). Não houve diferenças estatisticamente significantes (p>0,05) entre as radiografias panorâmicas e periapicais, assim como para as medidas obtidas com o paquímetro e pelo programa UTHSCSA Image Tool, quando comparados aos espécimes mandibulares, avaliando as distâncias 1 (p=0,783), 2 (p=0,986) e 3 (p=0,129). Em conclusão, as técnicas radiográficas avaliadas neste estudo mostraram-se confiáveis para mensurações ósseas verticais na área selecionada e o programa de digitalização de imagens UTHSCSA Image Tool é um método adequado de aferição.


Assuntos
Humanos , Cefalometria/normas , Mandíbula , Radiografia Interproximal/normas , Radiografia Dentária Digital/normas , Radiografia Panorâmica/normas , Processo Alveolar , Pontos de Referência Anatômicos , Cefalometria/estatística & dados numéricos , Processamento de Imagem Assistida por Computador/normas , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Reprodutibilidade dos Testes , Radiografia Interproximal/estatística & dados numéricos , Radiografia Dentária Digital/estatística & dados numéricos , Radiografia Panorâmica/estatística & dados numéricos , Software/normas , Software/estatística & dados numéricos
3.
Rev. odonto ciênc ; 25(3): 282-287, 2010. ilus, tab
Artigo em Inglês | LILACS | ID: lil-574137

RESUMO

Purpose: To determine the accuracy of different radiographic methods for bone height estimation at the mental foramen area. Methods: Twenty dry human hemimandibles were examed by using periapical and panoramic radiography, and computed tomography. An electronic digital caliper was used to measure the tracings obtained from the radiographies in three different times (groups A1, A2 and A3) and inthe cross-sectioned hemimandibles (group B). Measurements consisted of: Measure 1 - from the upper limit of the alveolar ridge to the upper limit of the mental foramen; Measure 2 - from the upper limit of the mental foramen to the inferior limit of the cortical bone of the base of the jaw; Measure 3 - from the upper limit of the alveolar ridge to the inferior limit of the cortical bone of the base of the jaw. Data were analyzed with Student-t and Friedman tests. Results: The average difference values in Measure 1 were 0.33 mm, 0.35 mm and 0.85 mm for the periapical radiography, computed tomography and panoramic radiography, respectively (confidence intervals of 0.17 mm to 0.49 mm, 0.18 mm to 0.53 mm and 0.38 mm to 1.32 mm, respectively). Panoramic radiographies showed the greatest differences in Measures 2 and 3, with average values of 1.05 mm and 1.93 mm, respectively. Conclusion: Periapical radiography and computed tomography showed the best accuracy. Asafety margin for surgical purposes has been suggested.


Objetivo: Determinar a acurácia de diferentes métodos radiográficos para estimação de altura óssea na região do forame mentual. Metodologia: Vinte hemi-mandíbulas humanas, secas, foram examinadas por radiografia periapical e panorâmica e tomografia computadorizada. Um paquímetro digital foi usado para medir os traçados obtidos das radiografias em três diferentes tempos (grupos A1, A2 e A3) e nas hemi-mandíbulas seccionadas transversalmente (grupo B). As medições foram: Medida 1 - do limite superior da crista óssea ao limite superior do forame mentual; Medida 2 - do limite superior do forame mentual ao limite inferior do osso cortical da base da mandíbula; Medida 3 - do limite superior da crista óssea ao limite inferior do osso cortical da base da mandíbula. Os dados foram analisados por teste t de Student e teste de Friedman. Resultados: Os valores médios de diferença na Medida 1 foram 0,33 mm, 0,35 mm e 0,85 mm para a radiografia periapical, tomografia computadorizada e radiografia panorâmica, respectivamente (intervalos de confiança de 0,17 a 0,49 mm, 0,18 a 0,53 mm e 0,38 a 1,32 mm, respectivamente). As radiografias panorâmicas mostraram as maiores diferenças nas Medidas 2 e 3, com valores médios de 1,05 mm e 1,93 mm, respectivamente. Conclusão: A radiografia periapical e a tomografia computadorizada mostraram a melhor acurácia. Sugere-se uma margem de segurança em caso de cirurgias.


Assuntos
Humanos , Diagnóstico por Imagem , Mandíbula , Radiografia Dentária , Radiografia Panorâmica , Tomografia Computadorizada de Feixe Cônico
4.
Rev. odonto ciênc ; 23(4): 333-337, out.-dez. 2008. graf, ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-500146

RESUMO

Purpose: This in vitro study evaluated the radiopacity of impression materials using an indirect digital system. Methods: Samples of four polyvinyl siloxanes, one polyether, one polysulfide, and one irreversible hydrocolloid were fabricated with 1.0, 1.5, and 3.5mm-thickness. Three samples of different thickness were placed on the Digora optical plate and exposed. The optical density (pixels) was recorded in three areas resulting in a total of 360 measurements. Data were analyzed by 2-way ANOVA and Tukey tests (α=0.05). Results: Significant differences were observed among all materials and thicknesses tested (P<0.001). Irreversible hydrocolloid and polyether showed the lowest optical density. Polysulfide showed the highest optical density under all evaluated conditions. Conclusion: There was a significant difference in optical density for all impression materials tested. Composition changes are suggested to allow radiographic detection and improve safety during clinical use of impression materials.


Objetivo: Este estudo in vitro comparou a radiopacidade de materiais de moldagem usando um método radiográfico digital indireto. Metodologia: Amostras de quatro polivinil-siloxanos, um poliéter, um polissulfeto e um hidrocolóide irreversível foram confeccionadas com alturas de 1, 1,5 e 3,5mm. Três amostras das diferentes espessuras foram dispostas sobre uma placa óptica Digora e exposta. A densidade óptica (pixels) foi registrada em três diferentes áreas de cada amostra. Os dados foram analisados pelo teste de análise de variância de dois fatores e teste de Tukey (α=0,05). Resultados: Diferenças significantes foram observadas entre todos os materiais e espessuras testadas (P<0,001). O hidrocolóide irreversível e o poliéter apresentaram a menor densidade óptica. O polissulfeto apresentou a maior densidade óptica em todas as condições avaliadas. Conclusão: Há diferença significativa na densidade óptica dos materiais de moldagem avaliados. Alterações na composição são necessárias para facilitar a detecção destes materiais a fim de aumentar a segurança no uso clínico.


Assuntos
Técnicas In Vitro , Materiais para Moldagem Odontológica/efeitos adversos , Radiografia Dentária Digital/métodos
5.
J. appl. oral sci ; 16(1): 55-58, Jan.-Feb. 2008. ilus, graf
Artigo em Inglês | LILACS | ID: lil-472690

RESUMO

Several authors still consider the mechanical problems of fracture and component loosening as the main causes of failure of implant-supported restorations. The purpose of this in vitro study was to compare the preload of three types of screw for transmucosal abutment attachment used in single implant-supported prosthesis through strain gauge and removal torque measurements. Three external hex fixtures were used, and each received a transmucosal abutment (Cera One®), which was fixed to the implant with its respective screw: Group A- gold screw, Group B- titanium screw and Group C- surface-treated titanium screw (Ti-Tite®). Ten screws of each type were attached applying a 30.07±0.28 Ncm torque force and maintained in position for 5 minutes. After this, the preload values were measured using strain gauges and a measurement cell. Gold screws presented higher preload values (131.72±8.98 N), followed by surface-treated titanium screws (97.78±4.68 N) and titanium screws (37.03±5.69 N). ANOVA (p<0.05) and Tukey's test (p<0.05) were applied. Statistically significant differences were found among the groups for both preload and removal torque values. In conclusion, gold screws may be indicated to achieve superior longevity of the abutment-implant connection and, consequently, prosthetic restoration due to greater preload values yielded.


Assuntos
Humanos , Dente Suporte , Implantes Dentários para Um Único Dente , Planejamento de Prótese Dentária , Materiais Revestidos Biocompatíveis/química , Retenção em Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Materiais Dentários/química , Ligas de Ouro/química , Teste de Materiais , Estresse Mecânico , Fatores de Tempo , Torque , Titânio/química
6.
Ciênc. odontol. bras ; 10(4): 61-69, out.-dez. 2007. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-500862

RESUMO

Verificou-se a densidade óptica de quatro resinas compostas disponíveis atualmente no mercado, bem como a composição desses materiais quanto à presença de elementos químicos responsáveis por sua densidade óptica. As resinas Z250 e Supreme (3M-ESPE), 4Seasons (Ivoclar Vivadent) e EsthetX (Dentsply), foram inseridas em orifícios existentes em 12 placas de acrílico divididas em espessuras de 2 e 4mm. Os incrementos de resina (2mm) foram fotopolimerizados por 40s. Realizaram-se 3 tomadas radiográficas de cada placa com o tempo de exposição de 0,12s. As imagens digitais foram obtidas através do sistema DenOptix. Foram realizadas 3 leituras de cada tomada radiográfica em cada resina no software VixWin, sendo calculada a média dos maiores e menores valores de densidade óptica (em pixels), totalizando 216 leituras. Confeccionaram-se 2 amostras de cada resina para análise dos elementos químicos em Microscopia Eletrônica de Varredura através de Espectroscopia por Dispersão de Energia (EDS). Os resultados foram submetidos ao teste de Shapiro-Wilk, à Análise de Variância, ao teste de Tukey a 1% e Correlação de Pearson. As médias de densidade óptica (pixels) em 2mm e 4mm, respectivamente, foram (valores seguidos de mesma letra não diferem estatisticamente entre si): Z250 = 171,17a e 199,58x; Supreme = 167,78a e 195,30w; 4Seasons =176,32b e 208,50y; EsthetX = 190,85c e 213,56z. Os maiores valores foram obtidos pela resina EsthetX, nas duas espessuras avaliadas. Com base nos resultados encontrados concluiu-se que não houve correlação entre os valores médios de densidade óptica das resinas testadas e o percentual em peso de elementos que lhe conferem esta característica.


Assuntos
Resinas Compostas , Materiais Dentários , Radiografia Dentária Digital , Interpretação de Imagem Assistida por Computador
7.
Rev. odonto ciênc ; 22(57): 222-227, jul.-set. 2007. ilus, tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-495270

RESUMO

O objetivo deste estudo foi comparar o desempenho de dois sistemas de medição de densidade óptica numa amostra composta por segundos molares decíduos, assim como relacionar a presença de lesão de cßrie dentinária na superfície oclusal de segundos molares decíduos com os valores de densidade óptica desta superfície, utilizando dois programas de computador. Para isso foi realizada a medição da densidade óptica de 28 radiografias padronizadas de segundos molares decíduos em dois programas de computador diferentes. Os resultados obtidos com o programa Digora® for Windows 2.1 foram comparados com os obtidos no programa Image Tool for Windows 3.0. Ainda, os valores de densidade óptica encontrados foram relacionados aos diagnósticos obtidos com o exame dos dentes no estereomicroscópio. Os programas Digora e Image Tool apresentaram valores de densidade óptica semelhantes, sem diferença estatisticamente significativa. Ainda, a densidade óptica observada nos dentes que não apresentavam lesões de cßrie dentinßrias na superfície oclusal foi diferente daquela cujos dentes possuiam lesão em dentina (p = 0,035). Entretanto, com os resultados obtidos neste estudo não foi possível estabelecer intervalos de densidade óptica correspondentes a superfícies oclusais com presença ou ausência de lesões de cßrie em dentina.


Assuntos
Cárie Dentária , Radiografia Dentária Digital , Dente Decíduo , Dente Molar
8.
Radiol. bras ; 40(3): 189-192, maio-jun. 2007. ilus, graf
Artigo em Português | LILACS | ID: lil-458041

RESUMO

OBJETIVO: Avaliar os efeitos da radioterapia e a acurácia da mensuração do nível de cinza do tecido ósseo em imagens radiográficas. MATERIAIS E MÉTODOS: Quatro ratos Wistar foram submetidos a radioterapia externa (dose única de 3.000 cGy) em uma área de 2 cm × 2 cm na perna direita. Os animais foram sacrificados seis semanas após a radioterapia, e tanto as pernas irradiadas quanto as contralaterais (não-irradiadas) foram avaliadas na sua espessura, radiografadas de forma padronizada e processadas histologicamente (hematoxilina-eosina e picrossírius). As radiografias foram digitalizadas e a média dos níveis de cinza foi mensurada no programa Image Tool®. RESULTADOS: A espessura do fêmur foi maior na perna contralateral do que na irradiada (p < 0,05). Radiograficamente, observou-se maior quantidade de tecido ósseo na perna contralateral em relação à perna irradiada, porém sem diferença estatística significante (p > 0,05). Histologicamente, foi possível observar, na perna irradiada, diminuição do número de osteócitos e dos canais de Havers, porém sem diferença estatística significante (p > 0,05). Por outro lado, foi observado aumento significante de adipócitos, com conseqüente diminuição de tecido medular na perna irradiada (p < 0,05) e maior atividade osteoblástica na perna contralateral (p < 0,05). CONCLUSÃO: A radioterapia, na dose aplicada, determinou diminuição da atividade de remodelação óssea, que pôde ser detectada radiograficamente na maioria dos espécimes avaliados.


OBJECTIVE: To investigate the effects of radiotherapy on bone tissues and the accuracy of gray level measurements on radiographic images. MATERIALS AND METHODS: Four Wistar rats were submitted to external radiotherapy (single 3000 cGy dose) on an area of 2 cm × 2 cm of their right legs. The animals were sacrificed six weeks after radiotherapy, and both irradiated and contralateral (non-irradiated) legs were removed, dissected, evaluated for thickness, x-rayed in a standardized form and histologically processed (stained with hematoxylin-eosin and picrosirius red). The radiographs were digitalized and the gray level average was measured with the ImageTool® software. RESULTS: The femur thickness of non-irradiated legs was greater than that of the irradiated legs (p < 0.05). Radiographically, the findings indicated a higher bone density in the non-irradiated legs, although with no statistically significant difference (p > 0.05). Histological analysis of the irradiated legs demonstrated a decrease in the number of osteocytes and Haversian canals, although with no statistically significance (p > 0.05). On the other hand, a significant increase in adipocytes was observed, resulting in a reduction of medullary tissue in the irradiated legs (p < 0.05), besides a higher osteoblastic activity in the non-irradiated legs (p < 0.05). CONCLUSION: Radiotherapy within the above mentioned parameters determined a decrease in activity of bone remodeling, which could be radiographically detected in the majority of the evaluated specimens.


Assuntos
Animais , Ratos , Osso e Ossos , Radioterapia , Fêmur , Lesões por Radiação , Ratos Wistar , Radioterapia/efeitos adversos
9.
Rev. odonto ciênc ; 21(53): 212-218, jul.-set. 2006. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-457360

RESUMO

Introdução: Embora os métodos de diagnóstico por imagem tenham evoluído permitindo um avanço na detecção precoce das doenças, o exame radiográfico convencional ainda é uma ferramenta importante para a avaliação da condição periodontal. Na literatura correlata existem poucas investigações sobre a especificidade da imagem radiográfica dos defeitos ósseos, evidenciando-se a necessidade de estudos adicionais sobre a temática. Objetivo: Descrever os aspectos radiográficos de defeitos ósseos periodontais produzidos artificialmente em mandíbulas secas, ressaltando os determinantes anatômicos que contribuem na formação dos diferentes tipos de defeito. Método: Foram utilizadas quatorze mandíbulas secas nas quais oito tipos de defeitos ósseos periodontais foram produzidos. Fotografias digitais e radiografias convencionais foram obtidas de forma padronizada de cada sítio, antes e após a confecção dos referidos defeitos. Em seguida, as radiografias foram dispostas em negatoscópio e avaliadas por três examinadores. Resultados: Os defeitos ósseos apresentaram características radiográficas distintas, em grande parte, permitindo sua identificação, com exceção dos defeitos de uma, duas e três paredes ósseas. O defeito do septo radicular foi o mais difícil de interpretação enquanto que os defeitos horizontal e vertical foram maisfacilmente interpretados. Considerações finais: A interpretação das imagens radiográficas de defeitos ósseos periodontais é dependente do tipo de reabsorção que está sendo avaliada. A descrição do defeito ósseo pode ser facilitada para aqueles tipos que apresentam a morfologia com menor superposição de estruturas óssea e dentária.


Assuntos
Humanos , Diagnóstico por Imagem , Doenças Periodontais/diagnóstico , Radiografia
10.
RFO UPF ; 11(1): 65-68, 2006. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-457212

RESUMO

O objetivo deste estudo foi comparar a densidade radiográfica dos cimentos de ionômeros de vidro (CIV) Ketac Fl Plus, Fujo IX e Vitremer, este último nas cores A3 e B2, inseridos em vinte placas de acrílico nas espessuras de 1,5 mm, 2,5 mm, 3 mm, 5 mm e 6 mm. Cada placa foi radiografadas três vezes,e as radiografias resultantes foram digitalizadas pelo sistema digital Dentscan DetnView. Nas imagens digitalizadas foram realizadas 720 leituras ópticas da densidade apresentada pelos CIV. De acordo com o resultado da análise de variância (Anova) e do teste de Turkey (p menor ou igual 0,01), sugere-se que a densidade radiográfica dos CIV estudados difere de acordo com a espessura e sua composição química


Assuntos
Cimentos Dentários , Cimentos de Ionômeros de Vidro , Radiografia Dentária Digital
11.
RFO UPF ; 10(2): 67-70, jul.-dez. 2005. tab, graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-442593

RESUMO

O objetivo da pesquisa foi comparar e correlacionar os níveis de cinza dos pinos intra-radiculares de fibra de vidro Fibrekor Post® (jeneric/Pentron) com a dentina radicular por meio dos sistemas digital Digora® e DentScan DentView®. A coroa de 22 incisivos centrais superiores foi secionada; os condutos radiculares, obturados pela técnica convencional e posteriormente preparados para receber os pinos de fibras de vidro com frequesas de 1,5mm de diâmetro do kit Fibrekor Post®. Foram realizados três sequências radiográficas, com filmes periapicais n 2 Ultraspeed® da Kodak, dos pinos no inteior do conduto e da dentina radicular, com técnica padronizada. As radiografias foram digitalizadas e os valores dos níveis de cinza foram obtidos pelas ferramentas dos sistemas digitais Digora® e DentScan DentView®, sendo posteriormente submetidos aos testes estatatístico t-student e de correlação de Pearson para uma probabilidade de erro de 1 por cento. Verificou-se que os valores médios dos níveis de cinza dos pinos nos interior dos condutos foram: 146,71 no sistema Digora® e 199,50 no sistema DentScan DentView®. Esses valores mostraram-se superiores aos da dentina radicular mesial e distal nos dois sistemas digitais. os níveis de cinza obtidos no sistema Digora® apresentaram um coeficiente de correlaçoa de Pearson positivo em relação ao DentScan DentView®. Conclui-se que os pinos de fibra de vidro Fibrekor Post® com 1,5 mm de diâmetro apresentaram uma imagem radiopaca no interior dos condutos radiculares dos incisivos centrais superiores


Assuntos
Humanos , Masculino , Feminino , Materiais Dentários , Pinos Dentários , Restauração Dentária Permanente , Dentina , Diagnóstico por Imagem , Técnicas In Vitro , Intensificação de Imagem Radiográfica
12.
Rev. odonto ciênc ; 20(50): 299-307, out.-dez. 2005. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-436387

RESUMO

Objetivo: Mensurar a densidade óptica das fibras de reforço Connect, Ribbond e Interlig incluídas em resina composta Filtek 2250, no sistema DenOptix®. Materiais e método: Foram confeccionados 10 blocos de resina composta associadas a cada tipo de fibra e dois blocos de resina Z250 pura (controle não-reforçado), totalizando 32 corpos-de-prova. Foram obtidas 3 radiografias digitais de cada corpo-de-prova, sobre uma placa óptica do sistema DenOptix®, para cada posição: (A) face lateral da fibra exposta aos raios-X; (B) face tramada da fibra exposta aos ralos-X. Em cada uma foram realizadas 3 leituras ópticas dos níveis de cinza em cada corpo-de-prova, em pontos aleatórios, sendo obtida uma média. Os valores médios dos níveis de cinza foram analisados pelo teste t de Student, ANOVA e teste de Tukey, ao nível de significâncla de 1 %. Resultados e conclusões: Com relação à associação da resina + fibra na posição (A), observou-se a maior média de níveis de cinza para a resina pura, seguido por resina + Connect, resina + Interlig (que não diferiram entre si), e resina + Ribbond. Com relação à associação da resina + fibra na posição (B), observou-se que a resina pura apresentou maior média, seguida por resina + Connect, resina + Interlig e resina + Ribbond, sendo que as duas últimas não foram diferentes entre si. Os resultados sugerem que os níveis de cinza variaram em função do tipo de fibra de reforço e da posição na radiografia


Assuntos
Bases de Dentadura , Intensificação de Imagem Radiográfica , Resinas Compostas
13.
PCL, Rev. Íbero Am. Prótese Clín. Lab. ; 7(37/38): 303-309, jul.-set./out.-dez. 2005. ilus, graf, CD-ROM
Artigo em Português | BBO - Odontologia | ID: biblio-853138

RESUMO

Os objetivos deste trabalho foram: 1) mensurar a densidade óptica (níveis de cinza) de pinos de fibra de carbono C-Post n. 1, 1,4mm de diâmetro (Bisco), no interior de condutores radiculares de 22 incisivos centrais superiores tratados endodonticamente com cimento a base de óxido de zinco e eugenol; 2) comparar os pinos pré-fabricados de fibra de carbono com a dentina mesial e distal adjacente, no programa Digora. Foi realizada uma sequência de tomadas radiográficas utilizando filmes InSight e simulador de tecido moles de cera utilidade de 1 cm de espessura nas raízes preparadas com o pino inserido nos condutos. Os filmes foram processados automaticamente numa processadora AT2000 da Air Techniques Inc. As radiografias foram escaneadas e digitalizadas no programa Digora, obtendo os valores de densidade óptica da dentina mesial e distal e do pino no interior dos condutos. Os resultados foram analisados estatisticamente por t-Student. Verificou-se que o pino dentro dos condutos apresentou valores de níveis de cinza (pixels) maiores que os das dentinas adjacentes mesial e distais. Os valores médios das dentinas mesiais e distais mostraram-se diferentes, ao nível de 1%


Assuntos
Dentina , Pinos Dentários/efeitos adversos , Radiografia Dentária , Carbono , Dente não Vital , Técnica para Retentor Intrarradicular
14.
JBP rev. Ibero-am. odontopediatr. odontol. bebê ; 8(43): 220-224, maio-jun. 2005. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-502342

RESUMO

A rizólise de molares decíduos é considerada fisiológica porém pode ocorrer de forma assimétrica provocando a reabsorção acentuada de uma das raízes. O objetivo deste trabalho foi determinar a prevalência de absorção assimétrica das raízes de molares decíduos inferiores e sua possível relação com o posicionamento do germe do pré-molar. Foram analisadas 192 radiografias panorâmicas do acervo das Disciplinas de Radiologia da PUCRS, de crianças com idade entre nove (quantidade: 110) e dez anos (quantidade: 82), pertencentes ao sexo feminino (quantidade: 95) e ao masculino (quantidade: 97). Observou-se que, dos 553 molares avaliados, 111 dentes (21%) apresentaram reabsorção assimétrica. Os segundos molares decíduos foram mais acometidos (72%) que os primeiros (28%) e a raiz mesial mais frequentemente reabsorvida (58,5%). Observou-se associação, estatisticamente, significativa (p<0,01) entre inclinação e deslocamento do germe do pré-molar com reabsorção acentuada de uma das raízes. Conclui-se que a reabsorção assimétrica ocorreu com relativa frequência, e observou-se que inclinação e deslocamento do germe do pré-molar foram importantes para esta condição.


Assuntos
Humanos , Masculino , Feminino , Criança , Dente Molar , Radiografia Dentária , Reabsorção da Raiz , Prevalência , Radiografia Panorâmica , Dente Decíduo
15.
Radiol. bras ; 38(2): 157-160, mar.-abr. 2005. ilus
Artigo em Português | LILACS | ID: lil-402652

RESUMO

O presente trabalho objetiva apresentar e discutir um caso clínico em que o fio de Kirschner foi empregado para fixação do osso zigomático fraturado, não sendo removido após quatro semanas, como recomendado pela literatura, comportando-se como corpo estranho, e sendo então removido.


Assuntos
Humanos , Masculino , Pessoa de Meia-Idade , Fios Ortopédicos , Corpos Estranhos , Fraturas Zigomáticas/reabilitação , Fraturas Zigomáticas , Fraturas Zigomáticas
16.
Rev. odonto ciênc ; 19(45): 250-257, jul.-set. 2004. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-412402

RESUMO

Este estudo mensurou os níveis de cinza de resinas de alta viscosidade (ALERT, PRODIGY CONDENSABLE, SOLITAIRE e SUREFIL) nas espessuras de 1, 2, 3 e 4 mm utilizando um sistema indireto de digitalização de imagem (DentScan DentView). Foram confeccionadas 20 placas de acrilíco transparente de 5,7 cm x 7,1 cm, que correspondem aproximadamente à área de um filme radiográfico do tipo occlusal, com espessuras de 1, 2, 3 e 4 mm. Cada placa foi dividida em 4 quadrantes e ao centro de cada quadrante foi confeccionado um orifício com 4 mm de diâmetro cada um e, cujas profundidades, foram correspondentes à espessura total de cada placa. Os orifícios serviram de sítio para as resinas a serem pesquisadas, que ali foram inseridas, condensadas e fotopolimerizadas. As vinte placas de acrílico foram fixadas sobre uma placa de vidro liso transparente, com 5 mm de espessura, que estava forrada por uma lâmina plástica para transparência recortada nas mesmas dimensões. A imagem radiográfica digitalizada foi obtida através de um scanner, com três vezes de aumento e o nível de cinza foi avaliado usando uma escala milimétrica. Para cada uma das 60 imagens radiográficas, foram realizadas 3 leituras ópticas, totalizando 180. Os valores dos níveis de cinza, para cada leitura de cada resina composta, foram registrados em planilhas e os dados analisados mediante os testes estatísticos de Kruskal-Wallis e Student-Newman-Keuls ao nível de significância de 5 por cento. Pode-se concluir, que a medida que aumentam as espessuras, correspondentemente aumentam as expressões de níveis de cinza das resinas estudadas. A resina Solitaire apresentou o menor nível mediano de cinza seguida pela Alert. A resina Surefil apresentou o maior valor mediano de nível de cinza entre todas as resinas. A resina Prodigy teve expressão de nível inferior ao da Surefil e maior do que o expresso pela Alert


Assuntos
Intensificação de Imagem Radiográfica , Resinas Compostas
17.
Rev. odonto ciênc ; 19(44): 122-125, abr.-jun. 2004. graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-397026

RESUMO

Foram analisadas 500 radiografias periapicais da região de canino inferior, dos lados direito e esquerdo, com o objetivo de quantificar a freqüência da protuberância mental nessa região, assim como verificar sua interferência na interpretação da região periapical desse dente. A projeção da protuberância mental esteve presente em 184 (36,8 por cento) radiografias e em 84 destas (45,6 por cento) observou-se interferência dessa estrutura sobre a raiz do canino. A modificação da angulagem vertical no sentido negativo, poderá possibilitar uma melhor visualização do ápice e da região periapical nesses casos


Assuntos
Dente Canino , Técnicas In Vitro , Mandíbula , Radiografia Dentária/métodos
18.
Rev. odonto ciênc ; 19(44): 131-138, abr.-jun. 2004. ilus, tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-397028

RESUMO

Objetivos: Analisar os níveis de cinza de pinos intrarradiculares de quartzo em radiografias digitalizados com filmes de diferentes sensibilidades. Metodologia: Foram selecionados 22 incisivos centrais superiores, que tiveram suas coroas seccionadas, seu canais tratados e preparados para receber o pino pré-fabricado Light-PostDT número 1. Após a verificação radiográfica da correta execução dos passos anteriores, radiografou-se o pino dentro do conduto dos espécimes com três incidências para cada amostra; este procedimento foi realizado com dois filmes de diferentes sensibilidades, com o tempo de exposição de 0,43 s para o InSight e 0,9 s para o Ultra-speed. Posteriormente foram feitas as digitalizações das imagens para leitura ótica das mesmas no programa Digora (Soderex). Resultados: O nível médio de cinza para o filme Ultra-speed dos pinos no interior de conduto foi de 249,35 e para dentina adjacente foi de 225,43; já no filme InSight o nível médio de cinza dos pinos no interior do conduto foi de 242,90e para dentina adjacente foi de 212,10. Ambos para um nível de significância de 1 por cento (p=0,010). Conclusão: Através do teste de comparação de médias pareadas t-Student, verificou-se que não houve diferença estatisticamente significante nos níveis de cinza entre as dentinas mesial e distal para ambos os filmes; já o pino apareceu com os níveis de cinza significantemente superiores à dentina adjacente. O filme InSight mostrou densidade óptica inferior no pino e na dentina adjacente com relação ao filme Ultra-speed


Assuntos
Diagnóstico por Imagem , Técnicas In Vitro , Pinos Dentários , Radiografia Dentária Digital , Restauração Dentária Permanente
19.
Braz. oral res ; 18(1): 40-44, jan.-mar. 2004. ilus, tab
Artigo em Inglês | LILACS | ID: lil-362049

RESUMO

O presente trabalho foi desenvolvido com o objetivo de analisar os níveis de cinza, expressos em "pixels", da região retromolar mandibular, considerando a influência dos tecidos moles muscular e, principalmente, adiposo adjacentes a essa região. Para o estudo, 15 mandíbulas secas foram tecnicamente radiografadas, sendo que as radiografias obtidas foram escaneadas e avaliadas pelo programa de imagens digitalizadas Digora®. Como simuladores dos tecidos muscular e adiposo, foram utilizadas cera utilidade na espessura de 1,0 cm e amostras de gordura animal em espessuras diferentes de 0,5; 1,0; 1,5 e 2,0 cm. Os resultados mostraram que o tecido adiposo foi capaz de influenciar a análise dos valores de níveis de cinza em "pixels" da região retromolar mandibular quando estudado em espessuras diferentes pelo programa de imagens digitalizadas Digora®.


Assuntos
Tecido Conjuntivo , Mandíbula , Radiografia Dentária Digital , Intensificação de Imagem Radiográfica/métodos , Modelos Teóricos , Músculo Liso Vascular , Músculo Liso , Interpretação de Imagem Radiográfica Assistida por Computador
20.
Rev. odonto ciênc ; 18(42): 350-353, out.-dez. 2003. graf
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-396977

RESUMO

Neste estudo foram examinadas 530 radiografias periapicais de região de incisivos inferiores, com o objetivo de identificar e quantificar a presença da eminêcia mental e sua interferência na interpretação dos ápices e periápices dos incisivos inferiores. Os resultados demonstraram que em 40 por cento dos casos esta estrutura estava presente e em 70 por cento destes existia interferência na visualização dos ápices dos incisivos inferiores. A variação da angulagem vertical pode minimizar esta ocorrência


Assuntos
Incisivo , Ápice Dentário , Técnicas In Vitro , Mandíbula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...